Wednesday, April 27, 2011
Monday, April 11, 2011
Full Adder
Problem: Design a full adder in Fluid logic. Following is the truth table of full adder circuit.
Download file in Fluid Sim 3.6 here:
Half Adder
Problem: Design a Half Adder circuit in Fluid Logic.
Download file in Fluid Sim 3.6 here:
Download File
Download file in Fluid Sim 3.6 here:
Download File
Sunday, April 10, 2011
Design: Vehicle Parking Area Problem
Problem: Design a logic(electrical or pneumatic), when any Vehicle near the entrance area the door automatically open when Vehicle enter the parking area door closed, and similarly when any Vehicle near the exit area which is already parked, the door automatically open, when Vehicle exit the exit door closed. Only 4 Vehicle allow in the parking, if 5th Vehicle near the entrance and 4 already in the parking area, the entrance door must not be open.
Friday, April 8, 2011
Drilling
Problem: Design a logic that drilling a square box all corners. Cylinder A and B holding th box and cylinder C drill it.
Download file in Fluid Sim 3.6 here:
Download File
Download file in Fluid Sim 3.6 here:
Download File
Filling Station using Level sensor
Problem: Design an electric circuit in which when Start button is pressed conveyer belt starts in which bottle is placed, these bottle pressed limit switch 1, after 3 sec, filling station start filling the bottle. A level sensor placed near the bottle, when bottle fill completely, level sensor sence it and filling station close and after 2 sec, conveyer belt start again for next bottle fill.
Download file in Fluid Sim 3.6 here:
Download File
Gets outputs in different interval when press button release
Problem: Design an electric circuit in which when Start button is pressed and released 3 output on each after 5 sec and then off each after 2 sec reversely.
Download file in Fluid Sim 3.6 here:
Download File
Single PRESS button perform many functions
Problem: Design an electric circuit in which when we press START button the filling station will OPEN for 2 sec, If we press again START button the filling station OPEN for 5 sec, If we press again START button the circuit will reset.
Download file in Fluid Sim 3.6 here:
Download File
Use of Solenoid Operated Valve
Problem: Design an electric circuit in which
SOV1 ON FOR 5 SEC THEN OFF
SOV2 ON FOR 5 SEC THEN OFF
MIXER ON FOR 5 SEC THEN OFF
SOV3 ON FOR 10 SEC THEN OFF
Download file in Fluid Sim 3.6 here:
Download File
Placement of items in different position
Problem: Design an electric circuit in which movable conveyer belt drop 5 box on position 1 and 10 box in position 2.
Download file in Fluid Sim 3.6 here:
Download File
Interlocking concept
Problem: Design an electric circuit in which when we press START button the Conveyer belt 1 (C.B.1) is ON and Proximity Sensor 1(P.S.1) sence 5 small boxes. After 5 boxes drop on large box Conveyer belt 1 STOP and C.B.2 start. When large box under droping position of small box, C.B.2 STOP and C.B.1 START again.
Download file in Fluid Sim 3.6 here:
Download File
Download file in Fluid Sim 3.6 here:
Download File
Gets output after releasing the button
Problem: Design an electric circuit in which is energized after release the button that 3 outputs ON with 0 sec delay and then go OFF each after 5sec.
Download file in Fluid Sim 3.6 here:
Download File
Delay between outputs
Problem: When a push button is presed an output 1 should be ON with 0 sec dealy and another output should be on with 5 sec delay. After energizing of both o/p, system should be reset after 5 sec.
Download file in Fluid Sim 3.6 here:
Download File
Download file in Fluid Sim 3.6 here:
Download File
Subscribe to:
Posts (Atom)